BGNWD - MDF-474 FIXER
- MSDS: BGNWD
- Manufacturer: MILLER DIAL CORP FOTOFOIL DIV
- Product Name: MDF-474 FIXER
- National Stock Number: 6750-01-145-7832
Product Identification
Product ID:MDF-474 FIXER
MSDS Date:11/01/1985
FSC:6750
NIIN:01-145-7832
MSDS Number: BGNWD
Responsible Party
EL MONT, CA 91734
Emergency Phone: 213-283-5111,POI.CNTR 212-340-4494
Info Phone: 818-444-4555 OR 800-423-4548
Cage: 91345
Contractor
Cage: 91345
Ingredients
AMMONIUM CHLORIDE (SARA III)
CAS: 12125-02-9
RTECS: BP4550000
Fraction By Weight: 1-5%
OSHA PEL 10 MG/M3/20 STEL
ACGIH TLV: 10 MG/M3 FUME; 9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
SODIUM SULFITE
CAS: 7757-83-7
RTECS: WE2150000
Fraction By Weight: 1-5%
ACETIC ACID
CAS: 64-19-7
RTECS: AF1300000
Fraction By Weight: <1%
OSHA PEL 10 PPM
ACGIH TLV: 10 PPM STEL 15 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Hazards
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:PRODUCT WILL IRRITATE EYES,SKIN,MUCOUS
MEMBRANES,G/I TRACT. PRODUCT IS NOT NORMALLY AN INHALATION HAZARD.
UNDER UNUSUAL CONDITIONS MAY PRODUCE FUMES OF ACETIC ACID OR SULFUR
DIOXIDE.
Effects of Overexposure:MAY CAUSE IRRITATION OF CONTACTED TISSUES.
Medical Cond Aggravated by Exposure:NONE REPORTED
First Aid
First Aid:EYE:FLUSH WITH WATER 15 MIN. SKIN:REMOVE CONTAMINATED
CLOTHING. WASH WITH SOAP & WATER. INHALED:REMOVE TO FRESH AIR.
INGESTED:GET IMMEDIATE MEDICAL ATTENTION.
Fire Fighting
Flash Point:NONE
Extinguishing Media:NONE REPORTED - USE MEDIA APPROPRIATE FOR THE
SURROUNDING FIRE.
Fire Fighting Procedures:NONE REPORTED
Unusual Fire/Explosion Hazard:NONE REPORTED
Accidental Release
Spill Release Procedures:ABSORB ON INERT MATERIAL.
Neutralizing Agent:SODIUM BICARBONATE MAY BE USED,BUT WILL NOT NORMALLY
BE NECESSARY.
Handling
Handling and Storage Precautions:STORE IN COOL AREA.
Exposure Controls
Respiratory Protection:NONE NORMALLY NEEDED. USE NIOSH ACID FUME
RESPIRATOR IF TLV'S ARE EXCEEDED.
Ventilation:NORMAL ROOM VENTILATION IS NORMALLY SUFFICIENT. USE LOCAL
EXHAUST TO MAINTAIN EXPOSURE BELOW TLV.
Protective Gloves:PLASTIC OR RUBBER
Eye Protection:SAFETY GLASSES OR GOGGLES
Other Protective Equipment:PLASTIC/RUBBER APRON
Work Hygienic Practices:USE NORMAL CHEMICAL HYGIENE PRACTICE.
Supplemental Safety and Health
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:212F/100C
Spec Gravity:1.280
pH:5.30
Solubility in Water:100%
Appearance and Odor:CLEAR COLORLESS LIQUID,VINEGAR ODOR
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS
Stability Condition to Avoid:HEAT
Hazardous Decomposition Products:SULFUR DIOXIDE
Disposal
Waste Disposal Methods:DISPOSE I/A/W FEDERAL,STATE,LOCAL REGULATIONS.
MFR:DILUTE 20:1;FLUSH TO DRAIN WILL BE OFTEN ACCEPTABLE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.